AVESTA - Spectrometer ASP-150C
  Spectrometer ASP-100M | Spectrometer ASP-150C | Spectrometer ASP-IR |

Spectrometer
Model: ASP-150C(150T)

Tunable *
Compact *
High resolution up to 0.017 nm *
USB interface *
No power supply unit *
Synchronization input/output *

Application
- Laser wavelength control
- Plasma control
- Luminescence control
- Precise analysis of different light sources

 
















Spectrometer ASP-150
ASP-150T
zoom in

   The ASP-150C spectrometer is an ideal choice for a wide variety of different optical applications with its flexible tuning and high resolution.
   The ASP-150T model is able to carry out measurements in a wider spectral range without any losses in resolution, owing to a special rotating mechanism.
   There is always a place for the ASP-150C on the optical table due to its small size, functionality and friendly interface.
    Models ASP-150CF and ASP-150TF have the special fiber input with a spectral slit, the size of which is conditioned with the detector. It allows measurement of either free-space or fiber signals without any realignment. However, it is not recommended to use fiber to measure spectrum of a femtosecond laser due to signal modulation and subsequent spectrum distortion.



ASP-150C(ASP-150T)
Optical scheme Cherny-Turner
Spectral range for choosing the registration domain, nm

190-1100

190-1100

190-1100

190-1100

190-1100

190- 800

190- 450

190- 300

Grating, grooves/mm 200 300 400 600 1200 1800

1800
II order

1800 III order

Registered spectrum region width, nm(1) 950 640 480 315 145 90 40 25
Spectral resolution, nm 0.6 0.42 0.3 0.2 0.09 0.06 0.025 0.017
Dispersion, nm/mm 33.2 22.4 16.8 11.0 5.1 3.1 1.4 0.9
Input slit, µm 10 
Focal length, mm 150
Focal length of the camera objective, mm 150
Relative aperture 1:13
Fiber input(2) FC, 400 µm UV fiber cable included (1 m.)
Synchronization external/internal
PC connection USB
Dimensions, mm 242x115x76 (ASP-150T); 205x115x76 (ASP-150C)
Weight, kg 1.6
CCD array specifications(3)
Model Toshiba 1205D Toshiba 1304AP Hamamatsu S8378-1024Q
Number of cells 2048 3648 1024
Cell width, µm 14 8 24
Cell height, µm 200 200 500
Minimum exposure time, ms 7 7 2.1

Maximum exposure time, s

4 0.5 5
Sensitivity(4), photons/count 80 20 650(3000)(5)
Antiblooming(6) yes no yes
Meansquare noise of reading, counts of ADC 5.4 3.5 16(4.4)(5)
ADC 12 bit, 4096 counts 12 bit, 4096 counts 14 bit, 16384 counts
Dynamic range 1000:1 1000:1 1000:1 (4000:1)(5)
(1) - the necessary width and center of the registered range should be specified when placing an order. The ASP-150T has an operational range adjustment function.
(2) - for models ASP-150CF and ASP-150TF.
(3) - any array can be combined with any grating type.
(4) - sensitivity given at the wavelength of 550 nm.
(5) - the Hamamatsu arrays provide for sensitivity control via special driving signal, that can set either low (values in brackets) or high sensitivity mode.
(6) - the property of the CCD to prevent the charge flow from the neighboring overexposed pixels.