AVESTA PROJECT - Scanning Autocorrelator AA-10DD
  Scanning Autocorrelator AA-10DD | Scanning Autocorrelator IRA-3-10 | Autocorrelator for Microscopy AA-M |

Femtosecond scanning autocorrelator AA-10DD

Pulse duration range 10-30000 fs *
Scanning rate 0.1-20 Hz *
Linear distortion <1% *
USB connection and software *
All-reflective optics *
Position measurement *
Fringe-resolved autocorrelation function *
Frictionless movement *
Optional fiber input *

Application:
- Femtosecond oscillator pulse duration measurement


What is the Interferometric Autocorrelation?
 


Femtosecond scanning autocorrelator AA-10D
AA-10DD
zoom in

 
AA-10DDM
zoom in

   The AA-10DD real-time autocorrelator offers smooth and fast measurement of femtosecond and picosecond pulse duration. Different models of the autocorrelator cover several wavelength ranges, with the AA-10DDM model combining the ranges by using 3 interchangeable photodetectors and optics. Two separate ranges can also be covered upon request. Input pulse duration ranges from 10 fs to 6 ps for easy monitoring of different laser systems, especially femtosecond and picosecond oscillators (for amplifier monitoring please also see our ASF-20 single-shot autocorrelator). The -30PS option widens the pulse duration range to 30 ps, while the -S option lowers the input repetition rate requirement to >10 Hz to fit almost any ultrafast system in the field.
   The device features USB interface and can be easily hooked up to a PC with Windows OS. The software is supplied with the device and comprises several useful tools. The acquired pulse duration data can be visualized, stored or exported to a .txt or .dat file. Autocorrelation function and final FWHM pulse duration in femtoseconds are calculated and displayed in real-time. Moreover, Gaussian or sech2 fitting options are enabled, intensity function may also be observed. The statistical viewer feature allows the comparison of data acquired from several separate pulse measurements.
   The tiny body of the AA-10DD (132x123x118 mm) flawlessly fits any experimental setup with strict space requirements. 
   We also offer an optional fiber input for fast and reliable pulse duration measurement in various optical fibers. Moreover, the autocorrelator in this case still maintians the free-space measurement capability.

AA-10DD
Wavelength range, nm 450-700 (AA-10DDV)
700-1300 (AA-10DD)
1300-2000 (AA-10DDR)
450-2000* (AA-10DDM)
Pulse duration range, fs 10-6000 (default); 10-30000 (-30PS option)
Input repetition rate >8 kHz (default); >10 Hz (-S option)
Sensitivity 100 mW2
Input polarization, linear horizontal (vertical upon request)
Scanning rate, Hz 0.1-20
Linear distortion, % <1%
Collinear (interferometric and intensity) autocorrelation yes
PC connection USB
Necessary equipment PC with Windows OS or oscilloscope
Fiber input (optional) FC/PC or FC/APC (other types available upon request)
Signal source and detector Two-photon conductivity in semiconductor
Dimensions, mm 132x123x118 (AA-10DD)
195x166x130 (AA-10DDM)

225x190x45 (electronic unit)
* - model AA-10DDM may cover either all three ranges (450-2000 nm) or two separate ranges (i.e. 450-1300 or 700-2000) with interchangeable optics and photodetectors (3 or 2 sets included).